From version < 1.4 >
edited by awa
on 21.11.2019, 10:20
To version < 1.3 >
edited by awa
on 21.11.2019, 10:04
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,47 +69,47 @@
69 69  
70 70  Regarding resetting the counter in daily intervals: Please note that the counter is not reset by background task, but only when the workflow action //counter// is executed. Or, to be more precise, the counter value is reset (instead of being incremented or decremented), when the time points at which the counter should have been reset contains at least one point that lies between the last point in time the counter value was modified and the current point in time.
71 71  
72 -; 1 - Condition
73 -: Lets you choose when and how the counter should be reset.
74 -:; Counter greater than or equal
75 -:: Available only when the counting action was set to //count up//. The counter is reset to its initial value when, after the counter was incremented, its value is now greater than or equal to the limit entered in (2).
76 -:; Counter less than or equal
77 -:: Available only when the counting action was set to //count down//. The counter is reset to its initial value when, after the counter was decremented, its value is now less than or equal to the limit entered in (2).
78 -:; daily
79 -:: The counter is reset each day at the time of day as entered in (2).
80 -:; weekly
81 -:: The counter is reset at each of the days of the week selected in (2); at the time of day as entered in (2).
82 -:; monthly
83 -:: The counter is reset each month at the date and time of day as entered in (2) and (3).
84 -:; yearly
85 -:: The counter is reset each year the the day, month and time of day as entered in (2), (3), and (4), respectively.
72 +; 1 - Bedingung
73 +: Hier kann festgelegt werden, wann und unter welchen Umständen der hler zurückgesetzt werden soll.
74 +:; Zähler größer gleich
75 +:: Nur verfügbar, wenn als Zählaktion //Hochzählen// gewählt wurde. Der Zähler wird auf den Startwert zurückgesetzt, wenn durch die aktuelle Aktion der Wert des Zählers so geändert wird, dass dieser größer oder gleich dem in (2) festgelegten Wert ist.
76 +:; Zähler kleiner gleich
77 +:: Nur verfügbar, wenn als Zählaktion //Herunterzählen// gewählt wurde. Der Zähler wird auf den Startwert zurückgesetzt, wenn durch die aktuelle Aktion der Wert des Zählers so geändert wird, dass dieser kleiner oder gleich dem in (2) festgelegten Wert ist.
78 +:; täglich
79 +:: Der Zähler wird jeden Tag zur bei (2) gewählten Uhrzeit auf den Startwert zurückgesetzt.
80 +:; wöchentlich
81 +:: Der Zähler wird an jedem unter (2) gewählten Wochentag zu der unter (3) gewählten Uhrzeit zurückgesetzt.
82 +:; monatlich
83 +:: Der Zähler wird jeden Monat zum unter (2) gewählten Tag zu der unter (3) gewählten Uhrzeit zurückgesetzt.
84 +:; jährlich
85 +:: Der Zähler wird jedes Jahr zum unter (2) und (3) gewählten Tag zu der unter (4) gewählten Uhrzeit zurückgesetzt
86 86  
87 -=== General return parameters ===
87 +=== Allgemeine Rückgabeparameter ===
88 88  
89 89  {{figure image="dbcounter_plugin_action_return_parameters_en.png"}}
90 -Settings for the return parameters of the counter action. You can access the returned values via variables.
90 +Einstellungen für die Rückgabeparameter, die später über Platzhalter verfügbar sind.
91 91  {{/figure}}
92 92  
93 -Sometimes it may be necessary to access the new value of the counter. To do so, you can use action variables for accessing the returned values of an action. The section //general return parameters// lets you configure the key you need to use for accessing the return values. For example, assume a counter action was named //CountUp//. Then you can use the variable //[%$CountUp.RESULT[0].count%]// to access the current counter value, provided you entered the key //count// in the input field (3). The following return values are available:
93 +Manchmal ist es notwendig, auf den neuen Zählwert zugreifen zunnen. Dies kann über Aktionsplatzhalter geschehen, welche auf die ckgabewerte einer Aktion zugreifen. In den allgemeinen Rückgabeparametern kann eingestellt werden, über welchem Schlüssel die Rückgabeparameter Aktion zugegriffen werden kann. Beispielsweise trage die Zähleraktion den Namen //CountUp//. Dann kann über den Platzhalter //[%$CountUp.RESULT[0].count%]// auf den aktuellen Zählwert zugegriffen werden, falls unter (3) bei den allgemeinen Rückgabeparameter der Wert //count// eingetragen wurde. Folgende Rückgabeparameter sind verfügbar:
94 94  
95 95  ; 1 - ResultCode
96 -: A numerical value that indicates whether the counter action was successful or not. The following result codes are possible:
96 +: Ein nummerischer Zahlenwert, der angibt, ob die Zählaktion erfolgreich war oder nicht. Folgende Ergebnisnummern sind möglich:
97 97  :; 1 (OK)
98 -:: The counter action was processed successfully.
98 +:: Die Zählaktion wurde erfolgreich abgearbeitet.
99 99  :; 10 (UNKNOWN_ACTION_ERROR)
100 -:: The counter action could not be processed, an unknown counting action was selected. The currently supported counting actions are //count up//, //count down// and //reset counter to start value//.
100 +:: Die Zählaktion kann nicht ausgeführt werden, da eine unbekannte Zählaktion ausgewählt wurde. Aktuell werden die Zählaktionen //Hochzählen//, //Herunterzählen// und //Auf den Startwert zurücksetzen// unterstützt.
101 101  :; 11 (PARSING_ERROR)
102 -:: A settings does not conform to the expected data type or syntax; such as when a letter was entered for the initial value (instead of a number).
102 +:: Ein konfigurierter Wert hat nicht den erwarteten Datentyp, etwa wenn für die Schrittweite des Zählers keine syntaktisch korrekte Zahl eingegeben wurde.
103 103  :; 40 (INTERNAL_ERROR)
104 -:: The counter action was not successful. The type of error cannot be specified more closely.
104 +:: Es ist ein anderer Fehler aufgetreten, der nicht näher klassifiziert werden kann.
105 105  ; 2 - ResultMessage
106 -: An English description of the result (success or error).
106 +: Eine englische Beschreibung des Resultats (Erfolg oder Fehler).
107 107  ; 3 - Counter
108 -: The new numerical value of the counter, after the counting action was applied.
108 +: Der neue nummerische Wert des hlers, nachdem die Zählaktion ausgeführt wurde.
109 109  ; 4 - IsReset
110 -: Either //true//, when the counter was reset during the current action; or //false// if it was not reset.
110 +: Entweder //true//, falls der hler durch die aktuelle Aktion zurückgesetzt wurde; oder //false//, wenn er nicht zurückgesetzt wurde.
111 111  ; 5 - CounterAfterReset
112 -: In case the counter was reset: The numerical value of the counter before the reset.
112 +: Falls der hler zurückgesetzt wurde: Der nummerische Wert des hlers vor dem Zurücksetzen.
113 113  
114 114  == Systemplatzhalter-Plugin ==
115 115  
Copyright 2000-2025